Carlon PVC Multi-Gard - Low Res Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Carlon PVC Multi-Gard - Low Res. Carlon PVC Multi-Gard - Low Res User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 5
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
www.carlonsales.com
6
Multi-Gard
®
PVC – Assembly/Field Cuts
Assembly
Field Cuts
1.
Distribute Multi-gard sections along
the sides of the trench with male ends
pointing towards starting vault entrance.
2.
Remove protective cap and
install Multi-Gard terminator on
male end. Install first section
into vault opening or enclosure
making sure the print line is on
the top stating INSTALL PRINT
LINE UP.” (See next page for
terminations.)
2. A spare spacer may be
installed to align the innerducts
if they seem loose.
2. Align innerducts on Multi-Gard section Awith
couplings on section B”. Solvent cement each coupling
for air tight seal and push until both ends are flush.
Apply solvent cement to both ends of Multi-Gard and
slide sleeve until it is centered on both sections.
3.
Each consecutive 20' section can now be
placed by inserting the male end into the gas-
keted belled end
1
/2
" to the gasket depth. Make
sure the print line is upright. (If not, rotate the
outer duct until it is.) Now push the sections
together with a firm push until belled end seats
against insertion line.
3. Raise both ends and align the innerducts
on the male end into the coupling body on
the female end. Lower both ends and the
innerducts will automatically return to their
original position as the joints are forced
together.
Joining Male and Female Ends
Joining Two Male Ends
1. Lay the Multi-Gard sections side by
side and mark the male end at the
base of the bell on the female end.
Make a straight cut using
a standard carpenter saw.
1. Flush cut Multi-Gard sections A + Bas shown in figure 1. Slide
outerduct sleeve over Multi-Gard section Bas shown in figure #2.
Insert end spacer into Multi-Gard plain end (chamfer side in) as
shown in figure #2. Press couplings onto innerducts of Multi-Gard
section Bas shown in figure #3.
FIGURE 1
FIGURE 2
FIGURE 3
M CC4
Gross Automation (877) 268-3700 · www.carlonsales.com · [email protected]
Vue de la page 0
1 2 3 4 5

Résumé du contenu

Page 1 - PVC – Assembly/Field Cuts

www.carlonsales.com6Multi-Gard®PVC – Assembly/Field CutsAssemblyField Cuts1.Distribute Multi-gard sections alongthe sides of the trench with male ends

Page 2 - PVC – Terminations

www.carlonsales.com7Multi-Gard®PVC – TerminationsStandard Terminators (Type 1) allow Multi-Gard to be terminated into a standard pre-cast termination.

Page 3 - PVC – Installation

www.carlonsales.com8Multi-Gard®PVC – InstallationAll PVC Trenching installation allowsMulti-Gard to be placed in the trenchone section at a time or ov

Page 4 - PVC – Repairs

www.carlonsales.com9Multi-Gard®PVC – RepairsRepairing Vacant Multi-GardRepairing Multi-Gard Containing Cable(s)1. Cut out the damaged sectionand inse

Page 5 - PVC – Repair Kits

www.carlonsales.com10Multi-Gard®PVC – Repair KitsRepair KitsRepairing Multi-Gard with Damaged CablesE940F PVC Coupling Couples PVC innerduct with sol

Commentaires sur ces manuels

Pas de commentaire